Customization: | Available |
---|---|
Application: | Nonwoven Microphone Cover |
Automatic Grade: | Automatic |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
NO | Part Name | manufacturer | Specification and description | Quantity | warranty period |
1 | control box | self made | Imported parts | 2 sets | 1 year |
2 | PLC | XINJE | Body and backend | 1 set and 2 sets each | 1 year |
3 | Ultrasonic equipment | 20k,2000W | 2 sets | 3 months | |
15k,2600W | 2 sets | 3 months | |||
4 | servo motor | Panasonic | 1500W | 1 | 1 year |
750W | 1 | 1 year | |||
400W | 2 | 1 year | |||
100W | 4 | 1 year | |||
5 | sensor | OMRON | 670/672/674 | 7 | 1 year |
6 | touch screen | XINJE | 7TG765 | 2 | 1 year |
7 | Bottom valve | SMC | 14 | 14 | 1 year |
8 | switch | MEANWELL | 200W,24V | 2 sets | 1 year |
9 | Cylinder | AirTac | Genuine original | 16 | 1 year |
10 | Panel switch | Schneider | Source: operation, stop, emergency | 8 8 | 1 year |
11 | Relay | OMRON | 24V | 6sets | 1 year |
12 | Knife mold | DC53, Tool | 2 | 3 months | |
DC53, Embossing knife | 2 | 3 months | |||
13 | Pneumatic scissors | Pneumatic scissors | 2 | 3 months | |
14 | magnetic | CHNT | 220V | 2 | 1 year |
15 | Speed motor | 1 | 1 year | ||
16 | AC motor | 3 | 1 year | ||
17 | Stepper motor | Leadshine | 57 | 1 | 1 year |
18 | Bottom plate | self made | 18mm S45C, Light chrome plating | 2 sets | 1 year |
19 | frame | self made | Welding of each pipe | 2 sets of spray paint | 1 year |
From outside to inside (240 or 260 width) | KG/capacity | ||
level one | SS grade 70g non-woven fabric | outward | 480 pcs |
Second floor | 99 grade 25g MB non-woven fabric | 960 pcs | |
Third floor | 99 grade 25g MB non-woven fabric | 960 pcs | |
Fourth floor | SS grade 25g non-woven fabric | Innermost | 960 pcs |
Ear line | 3.00MM ear cord, nylon, round shape, single wire is recommended | 2200 pcs | |
Bridge of nose | Double core 0.45mm * 3.0mm * 1.0mm, wire + PE material / PP material | 1250 pcs |
Remarks: The recommended materials for KF94 masks have a significant impact on the quality. The above table is for reference.
8, Matters needing attention
1. The main body of the equipment has a warranty period of 1 year, and the ultrasonic warranty period is 3 months.
2. We will ask customers to inspect before transporting this equipment. The inspection items include machine performance, smoothness, production capacity and yield. If the performance is required to be re-checked due to improper transportation or other human factors after delivery, the specific service amount will be specified in the consultation if the service can be provided for a fee.
3. Precautions when transporting the equipment: When transporting, please use a forklift or crane; when transporting, please be sure to fix it on the ground; when transporting, you must be especially careful to avoid damaging the wires or other parts. It can be transported directly by forklift or wheel. To prevent the four wheels at the bottom of the machine from being compressed for a long time, please move the machine to the designated position and fix the machine with food.
4. When connecting the power, please make sure that the main power circuit is correct before connecting.
5. Before setting or installing each component, please make sure to turn off the power switch or press the safety emergency switch.
6. After completing the settings of each part, make sure to tighten the bolts and nuts.
7. In an emergency or abnormal situation, you can stop the machine immediately by pressing the emergency switch to prevent operator safety and equipment damage.
8. Maintain the screw part of the machine by injecting lubricant.
9. The driving part of the machine should be lubricated regularly.
10. Use equipment according to equipment environment requirements.
9, Equipment use environment
1. Use the ambient temperature at room temperature.
2. The humidity requirement is 40%-80%, and constant temperature and humidity are required to prevent condensation.
3. Power requirements: 220V, 50Hz / 60Hz;
4. Voltage: ±5%. The ground wire must meet international requirements. In areas where the voltage amplitude is greater than or equal to 5%, an electronic voltage stabilizer must be installed.
5. There should be no strong electric signal near the equipment, and there should be no radio transmission station (or relay station) near the equipment.
6. Ground amplitude: within 50um; vibration acceleration: within 0.05g. There should be no equipment such as large presses in the vicinity of the installation, and the installation area should be free of smoke and dust, and avoid heavy metals and other grinding environments.
7. Compressed air pressure: 0.5-0.7Mpa.
8. In a specific environment, an anti-static floor should be installed to enhance the barrier.
10, Equipment maintenance
1. The equipment production workshop should always be kept clean and hygienic.
2. The exterior of the equipment should always be clean and kept clean.
3. Lubricant should be injected regularly into the operating part of the equipment.
4. If the equipment is not used for a long time, the equipment should be covered to prevent dust pollution.
5. If the equipment is not used for a long time, the main power supply must be cut off.
6. If the equipment is not used for a long time, please apply lubricant to prevent rust.